CodeDescriptionRemedy
C0001LCT Communication Failure
- Due to a software malfunction, etc., the time on the watchdog timer has run out and a reset is performed.
C0202Tray 1 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.
C0204Tray 2 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.
C0206Tray 3 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.
C0208Tray 4 Elevator Failure
- The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.
1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114-PF I/O check. 7 PC123-PF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124-PF operation check. 11 M125-PF operation check. 12 Change PWB-A. 13 Change PWB-C2. 14 Change PU1.
C0209LCT Elevator Motor Failure
- The Elevator Motor Pulse Sensor (PC10-LCT) cannot detect both edges of H/L even after the set period of time has elapsed while the Elevator Motor (M5-LCT) is turning backward/forward (raise/lower).
C0211Bypass Lifting Motion Failure
- The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Bypass Pick-Up Solenoid (SL3) is energized after the manual feed paper take-up operation has begun.
1 Check the SL3 connector for proper connection and correct as necessary. 2 Check cam position.. 3 PC29 I/O check PWB-A. 4 SL3 operation check. 5 Change PWB-A.
C0212LCT Ejection Failure
- See PC-407 sevice manual
C0213LCT Shift Gate Malfunction
- See PC-407 sevice manual
C0214LCT Shifting Failure
- See PC-407 sevice manual
C0215LCT Shift Motor Malfunction
- See PC-407 sevice manual
C0701Manual Paper Size Detection Adjustment Failure
- The control value of the Manual Paper Size Detection Unit does not fall within the specified range when an adjustment is made of manual paper size detection.
1 Check the VR1 connector for proper connection and correct as necessary. 2 Readjust the VR1. 3 Replace VR1. 4 Change PWB-A.
C1080Exit Option Communication Failure
- The connection status of a finishing option is changed after the copier has been turned on.
1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the PWB-A FN and the PWB-A for proper connection, and correct as necessary. 3 Change PWB-A FN. 4 Change PWB-A.
C1183Elevator Motor Ascent/Descent Drive Failure
- See FS-530/ PU-501/ OT-602 service manual.
C1190Aligning Plate 1 Drive Failure
- See FS-530/ PU-501/ OT-602 service manual.
CodeDescriptionRemedy
C1191Aligning Plate 2 Drive Failure
- See FS-530/ PU-501/ OT-602 service manual.
C11A0Paper-Lifter Drive Failure
C11A1Exit Roller Pressure/Retraction Failure
- See FS-530/ PU-501/ OT-602 service manual.
C11A2Saddle Exit Roller Pressure/ Retraction Failure
-See SD-507 service manual.
C11A3Shutter Drive Failure
- See FS-530/PU-501/OT-602 service manual.
C11A4Saddle Exit Motor Failure
- See SD-507 service manual.
C11A5Saddle In & Out Guide Motor Failure
- - See SD-507 service manual.
C11A6Saddle Layable Guide Motor Drive Failure
- See SD-507 service manual.
C11B0Staple Unit CD Drive Failure
- See FS-530/PU-501/OT-602 service manual.
C11B2Staple Drive Failure
- See FS-530/PU-501/OT-602 service manual.
C11B5Saddle Staple 1 Drive Failure
- See SD-507 service manual.
C11B6Saddle Staple 2 Drive Failure
- See SD-507 service manual.
C11C0Punch Cam Motor Unit Failure
- See FS-530/PU-501/OT-602 service manual.
C11D0Crease Motor Drive Failure
- See SD-507 service manual.
C2211IU Motor Failure
- The IU Motor Lock signal remains set to H for a set period of time while the IU Motor is turning.
- The IU Motor Lock signal remains set to L for a set period of time while the IU Motor remains stopped.
1 Check the M2 connector for proper connection and correct as necessary. 2 Check the M2 for proper drive coupling, and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M2 operation check PWB-A PJ28A-11 (REM) M-4 5 Change PWB-A. 6 Change PU1.
351Toner Suction Fan Motor Failure
- The Toner Suction Fan Motor Lock signal remains set to H for a set period of time while the Toner Suction Fan Motor is turning.
- The Toner Suction Fan Motor Lock signal remains set to L for a set period of time while the Toner Suction Fan Motor remains stopped.
1 Check the M11 connector for proper connection and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M11 operation check PWB-A PJ5A-13 (REM) D-14 5 Change PWB-A. 6 Change PU1.
C2431IU Fuse Blowing Failure
- The fuse is not blown even after the lapse of a predetermined period of time.
1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.
C2557ATDC Sensor Failure
- The scanning value of the ATDC Sensor is less than 7 % while the IU Motor is turning.
- The scanning value of the ATDC Sensor is more than 19 % while the IU Motor is turning.
1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.
C255CATDC Adjustment Failure
- The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run.
- The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run.
1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB-A. 5 Change PU1N.
C2654EEPROM Failure
- An EEPROM where no initial data is written is detected
1 Disconnect and then connect the power cord. Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the EEPROM on the Mechanical Control Board for proper connection, and correct as necessary. 3 Change PWB-A. 4 Change EEPROM.
C2702Abnormal Image Transfer Voltage
- The image transfer voltage exceeds 100 V for the set period of time while the IU Motor remains stopped.
1 Check the installation of the Transfer Roller. 2 Change HV1
C3451Fusing Warm-Up Failure (Main)
- The Fusing Roller Thermistor does not detect the required temperature within 30 sec. after a warmup cycle has begun; therefore, the copier does not complete the warm-up cycle.
- The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle.
1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
C3452Fusing Warm-Up Failure (Sub)
- The Fusing Roller Sub Thermistor does not detect the required temperature within 30 sec. after a warm-up cycle has begun; therefore, the copier does not complete the warm-up cycle.
- The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle.
1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
C3751High Fuser Temperature Failure (Main)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON.
1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
C3752High Fuser Temperature Failure (Sub)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON.
1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
C3851Low Fuser Temperature Failure (Main)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing.
1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
C3852Low Fuser Temperature Failure (Sub)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing.
1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB-A.
C4001Main body Communication Failure
Communications with the Mechanical Control Board and the MFBS Board/MFBS2 Board fail.
1 Check the MFBS/MFBS2 connector for proper connection, and correct as necessary. 2 Check the PWB-A connector for proper connection, and correct as necessary. 3 Check the flat cable between MFBS/MFBS2 and PWB-A for proper connection, and correct as necessary. 4 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 5 Change MFBS/MFBS2. 6 Change PWB-A.
C4002HSYNC Detection Failure
- No SOS falling edges are detected within the set period of time after laser emission began while the Polygon Motor is turning.
- No SOS falling edges are detected while VIA remains ON.
1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the PH and the PWB-A connectors for proper connection, and correct as necessary. 3 Change PH. 4 Change PWB-A.
C4101Polygon Motor Failure
- The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection)
- No First Lock signals are detected during the 1- second period that starts 1 second after a First Lock signal. (Faulty lock signal detection)
- The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out-of-timing lock detection)
- The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection)
1 Check the PH connector for proper connection, and correct as necessary. 2 Change PH. 3 Change PWB-A.
C4721Main Body G/A Communication Failure
- Communications with the gate array for expansion I/O (the IC mounted on the Mechanical Control Board) fail.
1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check each control board and the PWB-A for proper connection, and correct as necessary. 3 Change PWB-A.
C5102Main Motor Failure
- The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning.
1 Check the M1 connector for proper connection, and correct as necessary. 2 Check the M1 for proper drive coupling, and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M1 operation check PWB-A PJ28A-4 (REM) M-4 5 Change PWB-A. 6 Change PU1.
C5351Power Supply Cooling Fan Motor Failure
- The Power Supply Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Supply Cooling Fan Motor is turning.
- The Power Supply Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Supply Cooling Fan Motor remains stopped.
1 Check the M4 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M4 operation check PWB-A PJ33A-1 (REM) D-5 4 Change PU1.
C5352Cooling Fan Motor Failure
- The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning.
- The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped
1 Check the M5 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M5 operation check. 4 Change PWB-A.
C5353IU Cooling Fan Motor Failure
- The IU Cooling Fan Motor Lock signal remains set to H for a set period of time while the IU Cooling Fan Motor is turning.
- The IU Cooling Fan Motor Lock signal remains set to L for a set period of time while the IU Cooling Fan Motor remains stopped.
1 Check the M6 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Change PWB-A.
C7001Engine connection error
- The system fails in checking initial engine connection when the Power Switch is turned ON.
- The system succeeded in checking initial connection when the Power Switch was turned ON; then it fails in rechecking initial connection through the execution of a software reset when a communications error occurs during operation.
1 Check the connection between Mechanical Control Board and BCRS Board. 2 Reset the malfunction and turn OFF and ON the Power Switch. 3 Change BCRS. 4 Change PWB-A.
C8301ADF Fan Motor Failure
- See DF-620 service manual.
C9701ADF Document Size Failure Adjustment
- See DF-620 service manual.
CA052MIO Device Failure
- The MIO device does not operate properly
1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the BCRS connectors for proper connection, and correct as necessary. 3 Change BCRS.
CC153Flash ROM Failure
- The Flash ROM data was determined to be faulty when the unit was turned on.
1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 The firmware data is overwritten. 3 Change PWB-A.
CC155Exit Option Flash ROM Failure
- See FS-530/PU-501/OT-602 service manual.
CD004HDD error
- When error occurs during deletion of HDD data.
1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check theHard Disk connector for proper connection and correct as necessary. 3 Reinstall the Hard Disk. 4 Change Hard Disk. 5 Change MFBS/MFBS2.